Sensor taps fail at the solenoid and the power supply more often than at the cartridge, and the fix starts with which of the two is dead.

A tap with three systems

A sensor tap is a normal faucet with two added systems: a sensing circuit and a solenoid valve that opens when the sensor trips. When it misbehaves, the fault is more often in those two systems than in the valve body itself.

That changes the diagnostic order. On a manual tap, a drip is a sealing problem. On a touchless tap, the first question is whether the tap responds at all, because a tap that will not run and a tap that will not stop point to opposite ends of the same circuit.

The checks that settle it

  1. Power. Most sensor taps run on batteries, some on a low-voltage transformer, some on both. A failing battery pack produces exactly the symptoms people describe as a broken sensor: intermittent operation, then nothing. Replace the batteries with fresh ones before diagnosing anything else.
  2. Manual override. Many models have an override that runs the tap without the sensor. If the tap works in override, the solenoid and the water path are fine and the sensor or its power is the fault.
  3. The screen. Sensor taps have an inlet screen or filter ahead of the solenoid. Hard water scales it, and the tap slows to a trickle. Alhambra's groundwater averages 240 mg/L total hardness, so this is a routine finding rather than an unusual one.
  4. The solenoid. A solenoid that clicks but does not open is usually scaled or failed. One that does not click at all is a power or sensor problem.
  5. The sensor window. Dirt, soap film or a scratched lens can make the tap trigger on its own or not at all. Clean it before replacing anything.

Water that will not stop

A touchless tap that runs continuously is the urgent version of the fault. The usual cause is a solenoid stuck open, and the immediate action is the stop under the sink or the fixture's own supply valve. If the stop will not close, the water has to come off at the unit or building main — which on a multi-unit building is the reason to know where that main is before an emergency.

What replacement involves

Replacing a body in the same hole is a fixture change, which Alhambra's section 107.2(b) exemption covers where the waste and vent piping stay. Replacing the solenoid or the sensor on an existing body is a repair to the fixture's valve, which section 107.1 puts under permit. For a commercial installation the scope usually includes wiring or a transformer, and that is a separate electrical question.

The Building Division can confirm scope, and applications go through the Permit Portal.

Commercial and rental settings

In a commercial restroom, a sensor tap that fails is a closing-time problem, and the manual override is what keeps the room usable until the part arrives. In a rented unit, the tenant usually cannot reach the stop, so the first call is to the owner or manager.

Where the work fits

Manual single-handle bodies are covered under cartridge replacement, and a complete fixture swap under replacement. Commercial restrooms are covered separately in commercial faucet repair.

Ramona Park, California