Electrical before plumbing
A sensor tap has a water path and a control path, and the control path fails first in most cases. If the fixture shows no light and makes no sound when a hand passes under it, the fault is almost certainly in the supply of power rather than in the water.
That is why the model number matters so much at a Wilmar address. Washrooms along Garvey and in the small offices behind it may be fitted with any of several makes, and each publishes its own fault table and reset procedure. Without the number, a diagnostic light can only be read as a guess.
The checks that come first
Confirm the batteries are the right type and seated properly, and that any power and data cables are fully pushed home at the control box. A partly seated plug produces the erratic behaviour that looks like a failing sensor: a tap that works sometimes, or triggers when nobody is near it.
On a recent installation, protective film on the sensor is worth checking, and the fixture may need to finish its own start-up routine before it responds.
When the fault moves to the water
A sensor that triggers with no water flowing points at the valve side and its inlet strainer, which is ordinary plumbing work: isolate the fixture, open the valve component, clean or renew it, flush and reassemble. On a business premises, the isolation point is worth confirming before the visit.
Restoring factory settings is a published step on current models and clears a mis-set detection range as well as a confused state, so a reset usually comes before any part is condemned.
Cost and next steps
The variables are the model, the power arrangement and whether the valve side needs cleaning. A fixture that only needs batteries or a reseated cable is a short visit; one that needs a valve component is a parts order.
The touchless faucet repair service page explains the components, and commercial faucet repair covers a washroom that has to stay usable.