Diagnose the sensing side first
A sensor tap contains a valve body, a sensing circuit and a solenoid. The valve body rarely fails; the other two do, and separating them is the first move.
Battery or power pack. Intermittent triggering that decays into nothing is the classic signature. Commercial installs may run on mains power through a transformer, in which case the check moves to the supply.
Manual override. Hold the override or use its button. If water runs, the solenoid and the water path are sound and the fault is in sensing. If nothing happens, the problem is downstream of the circuit.
The lens. Soap film, mineral haze and scratches cause both phantom starts and missed triggers, and cleaning it is a two-minute test.
Once those are excluded, the remaining candidates are the solenoid, the screen ahead of it and the control module.
When it will not shut off
A sensor tap that keeps running is urgent, and the cause is normally a solenoid stuck open. Close the stop under the sink or the fixture's own supply valve immediately; a restroom that cannot be closed floods a floor in minutes.
In this city's 1950s houses, the stop under a vanity is often the original multi-turn valve and may not close. That turns an urgency into a main shutoff, and it is worth testing the stop before there is a reason to need it.
Cleaning a screen on this supply
The fixtures here are fed by San Gabriel Valley Water Company, which treats basin groundwater for solvents and perchlorate but does not soften it. Sensor taps carry a fine screen ahead of the solenoid, and that screen is where the deposit lands first. A tap that dribbles rather than runs is usually that screen, not the valve.
Retrofitting an old deck
Original tops in this stock are four-inch centreset with a shallow cabinet. A sensor body needs a hole for its lens, room for a control box, and clearance for the battery pack or transformer.
In a mobile home, one unit in ten of the housing here, the cabinet is shallower again and the supply arrangement differs, so the measurement comes before the order.
Commercial scheduling
A shop or restaurant restroom cannot wait days with its only tap out of service. Two city facts set the pace: inspections are held only on Monday, Wednesday and Thursday by appointment with 24 hours' notice, and permits are applied for through the Online Permit Portal at the Building & Safety Division.
For a replacement body, the person pulling the permit must hold a current Contractor's Registration License with the city. A same-day repair of a solenoid usually avoids all of it.
Where the work fits
Manual single-lever bodies: cartridge replacement. A dead fixture: replacement. Shop restrooms: commercial faucet repair.